3 6 installation, For qualified installers only) – Avalon Firestyles 564 SS Gas Installation User Manual

Page 36

Advertising
background image

3 6

Installation

(for qualified installers only)

Travis Industries

4 0 7 0 6 2 0

100-01188_000

Thin Facing Installation (tile, marble, or other non-combustible under 1" thick)

Upgrade faces are available for this fireplace and may influence facing installation. Consult with your

Travis Dealer if you are using an upgrade face.

Do not install tile (or other material)
in front of the glass frame,

convection channel, or access panel

openings. This area must remain

open to access internal components
and for convection air.

Raised Fireplaces:

Facing is installed 1” (maximum)
above the base of the fireplace.

Facing is installed to this

edge of the fireplace.

FRONT VIEW

Tile Line

Tile Line

Hearth Line

Tile Line

27-3/4”

1”

1-7/8”

32-1/2”

1-1/2”

NOTE FOR FPX FACES:

FPX arched faces require the FPX Face Upgrade

Kit (sku 98500683) and a triangular piece of

facing in these upper corners. See the
instructions included with the face for further

details.

7-1/2”

1-5/8”

Fireplace

Drywall

Framing

Nailing Bracket

Tile

TOP VIEW

Drywall

Floor-Mounted Fireplaces or Raised Hearths:
Build the hearth 1” (max.) above the base of the

fireplace. The fireplace may be raised to

accommodate thicker hearth materials.

Advertising