Finalizing the Installation

(for qualified installers only)

4 5

© Travis Industries

4 0 7 0 6 2 0

100-01188_000

8.

Check the air shutter following the directions below.

Air Shutter Adjustment

Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be
yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.

Correct

Flames should be blue at the
base, yellow-orange on the top.

If the flames are over 14" tall or sooty on
the ends, open the air shutter.

Not Enough Air

If the flames are all blue and
short, close the air shutter.

Too Much Air

Front Air Shutter Adjustment

The front burner air shutter may be adjusted while the burner is on (take care to prevent contacting the burner
area).

Front Burner Air Shutter Control

Left = Less Air

Right = More Air

Rear Burner Air Shutter Control

Left = Less Air

Right = More Air

NOTE: you may wish to use pliers to

adjust the front air shutter.

Typically, the front air shutter is fully

closed (left) on NG, fully open (right)

on LP

9.

Turn the flame adjust knob to its highest position - the flames should not contact the top of the
firebox. Check the flame on low position. The flames should burn off of each burner hole. If the
heater does not work correctly, contact your Travis dealer for a remedy.

10.

Give this manual to the home owner for future reference and fully explain operation of this heater. For

comprehensive operating and maintenance instructions, refer to the Owner's Manual (part # 100-
01189).

ACID WASH WARNING: Before installing the faceplate, make sure any masonry that has been treated
with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic
acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution, the plated
face may develop a permanent tarnish when the acid evaporates over time. Contact your dealer if
uncertain your facing has been properly neutralized.