GS k 70 n d
1
…d
n
[Function]
Prints an ITF barcode
[Format]
ASCII
GS
k
70
n
d
1
…d
n
Hexadecimal
1D 6B 46 n d
1
…d
n
Decimal
29 107 70 n d
1
…d
n
[Description]
It is a copy of the command GS k 5 d
1
…d
n
NUL
GS k 6 d
1
…d
n
NUL
[Function]
Prints a CODABAR barcode
[Format]
ASCII
GS
k
6
d
1
…d
n
NUL
Hexadecimal
1D 6B 06 d
1
…d
n
00
Decimal
29 107 6 d
1
…d
n
0
[Description]
d
1
…d
n
is the sequence of n bytes containing the barcode information.
The bytes that can be used in d are 36, 43, 45 to 57 and 65 to 68
(upper case letters) or 97 to 100 (lower case letters). Lower case and
upper case letters can’t be combined in the same barcode. A check
sum digit will be added automatically. Number of digits in the barcode
limited by the print field as well as the configured barcode width. If the
first character is a letter, the last character must also be a letter.
Excluding these two characters (the first and the last one), any other
character can be a letter.
GS k 71 n d
1
…d
n
[Function]
Prints a CODABAR barcode
[Format]
ASCII
GS
k
71
n
d
1
…d
n
Hexadecimal
1D 6B 47 n d
1
…d
n
Decimal
29 107 71 n d
1
…d
n
[Description]
It is a copy of the command GS k 6 d
1
…d
n
NUL