Digi-Star TCX-1000 SERIES User Manual
Page 23
D3556 05/29/03 REV. 2.2
Copyright 2001
23
Note: If D.C. power drops below 8.7 volts, the indicator will flash LobAtt. If the input voltage
drops below 5.5 volts, the indicator will reset itself.
C.
LOAD CELL CABLE INSTALLION INSTRUCTIONS
Disconnect the main D.C. power line from the indicator.
The lad cell cable should be a shielded cable. Terminate the shield
Strip the insulation off each conductor wire of the cable back 3/8” from wire end.
Crimp and solder the supplied male AMP pin to the appropriate conductor wire.
Insert the pin into the appropriate AMP connector plug hole, according to the load cell connections
chart in this section.
D.
SET POINT CONNECTION
SETPOINT WIRING CHART FOR TERMINAL BLOCK TB1
TB1 POSITION NUMBER
DEFINITION
1 SETPOINT
#8
2 +5
VOLTS
3 GROUND