Note: If D.C. power drops below 8.7 volts, the indicator will flash LobAtt. If the input voltage
drops below 5.5 volts, the indicator will reset itself.

C.

LOAD CELL CABLE INSTALLION INSTRUCTIONS

Disconnect the main D.C. power line from the indicator.
The lad cell cable should be a shielded cable. Terminate the shield
Strip the insulation off each conductor wire of the cable back 3/8” from wire end.
Crimp and solder the supplied male AMP pin to the appropriate conductor wire.
Insert the pin into the appropriate AMP connector plug hole, according to the load cell connections
chart in this section.



D.

SET POINT CONNECTION

SETPOINT WIRING CHART FOR TERMINAL BLOCK TB1

TB1 POSITION NUMBER

DEFINITION

1 SETPOINT

#8

2 +5

VOLTS

3 GROUND