Digi-Star TCX-1000 SERIES User Manual

Page 37

Advertising
background image

D3556 05/29/03 REV. 2.2

Copyright 2001

37

S Stainless Steel (When used as the second suffix)
B Panel Mount
-B 12 VDC Battery Option (The 12 VDC power supply version has an option to set the Auto-Powerdown
timer, Low-Battery Powerdown timer and LCD Backlight off timer.)
-L Liquid Crystal Display
Temperature Range: -10 °C to 40 °C (14°F to 104 °F)

Certificate Number: 01-060



Digi-Star LLC
Digital Electronic Element
Models: TC-10 and TCX-1000

Application: General purpose indicating elements.

Identification: The identification badge is located on the top of the indicator. It is a self-destructible
adhesive badge.

Sealing: All models require a wire security seal. The TC-10 D desk mounted version is sealed using a wire
seal through the heads of two screws located on the back of the case. The TC-10 W wall mounted version is
sealed using a wire security seal through two holes in the cover and housing. The TC-10 B panel mounted
version is sealed using a wire security seal through two sealing screws on the left side of the indicator case.
The TC-10 WS stainless steel wall mounted version is sealed using a wire security seal through a sealing
screw and a hole in a tab located on the lower left side of the indicator. The TC-10 S and all of the TCX-
1000 models are sealed by using a wire security seal through the four corner screws of the cover and holes
in the cover.

Test Conditions: This certificate supersedes Certificate of Conformance number 89-086A4 and is issued to
indicate the transfer of ownership from Tyrel Corp. to Digi-Star LLC. The NTEP Certificate of
Conformance 89-086A4, though inactive, remains in effect to cover those devices previously sold and
installed under the original name. Previous test information and documentation provided by the company
was reviewed. The test conditions for the original type evaluations are listed below for reference.

Certificate of Conformance No. 89-086A4: This Certificate supersedes Certificate of Conformance No.
89-086A3 and is issued to include the Model TCX-1000 and include the 12 VDC battery option. The
Model TCX-1000-B was tested at –10 °C to verify operation of the LCD display at low temperatures.
Additionally, low battery tests were conducted using a variable DC voltage power supply.

Certificate of Conformance No. 89-086A3: This Certificate supersedes Certificate of Conformance No.
89-086A2 and is issued to remove the B option for use of a 12 VDC power input instead of 117 VAC
power. No testing was done with this power source and the B option was included in error. Test conditions
for Certificate of Conformance No. 89-086A2 have been revised to remove the reference to the B option.

Certificate of Conformance No. 89-086A2: This Certificate supersedes Certificate of Conformance No.
89-086A1 and is issued to include the -L suffix. The addition of the suffix has no metrological effect on the
device, and no formal testing was required.

Certificate of Conformance No. 89-086A1: This Certificate supersedes Certificate of Conformance 89-
086 and was issued to add optional Model TC-10A. Model TC-10A is the same as Model TC-10 except
that it has extra keys on the front panel to prevent operator errors and a two digit display to show the cut-off
set point. Two internal changes were made to automatically set the dead load and gain switch during
calibration.

Certificate of Conformance No. 89-086: The emphasis of the evaluation was on the device design,
operation, and compliance with influence factor requirements. The indicator was interfaced with an