8
Lock-On-Store Send
LSSEND is for LSTORE automatic modes and
has no effect in manual modes.
If set to “OFF”, data is sent when animal steps
off the platform.
If set to “ON”, data is sent as soon as the
scale locks-on.
If set to “ON”, press [RECHECK] to recheck
the weight and send new data to computer
port.
- .
One Touch Zero
Set to “On” to zero scale by pressing [Zero]
only.
Set to “Off” to zero scale by pressing
[Gross/Net] and [Zero].
Tare Auto Print
Set to “ON” to print data when the indicator
“TARE” function is used.
One Line Print
Set to “ON” formats printer output data on one
line. Set to “OFF” formats printer output data
in up to two lines.
Scoreboard Mode
Selects one of several methods to
continuously output display data to a
scoreboard via com port. See “Appendix E”
for details.
Auto Print
When set to “ON”, pressing keys will
automatically print weight values.
#
)
Com In
Interface selections,
= Data Down
Loader,
= Original EZ Commands &
!
= EZII Escape Commands.
%
Print Format
Many data output formats are available. See
“Appendix F” for details.