Select weigh method #4 for animal weighing. If you choose to use the
StockWeigh 600 for weighing dead loads, you can still use the Lock-On
Weigh method but you may wish to use one of the other methods listed
below.
!3
#%45
The General weigh method is an all-purpose weigh method for weighing
dead loads. It is used for most applications.
!
#2 3
#%46
The "Slow" weigh-method attempts to provide higher accuracy by
filtering many weight samples over a longer period. This method is for
weighing dead loads.
+ $ 3
#%47
The Fast weigh method is more sensitive to weight changes than the
other weigh methods. When a weight changes quickly, the Fast method
tries to determine the new weight as quickly as possible. This method
is for weighing dead loads.
# 83
3
#%49
Set to “LOCKON” for animal weighing, this allows scale to weigh active
animals and display an accurate weight that does not fluctuate. Set to
“OFF” for weighing dead weights. Lock-On sensitivity can be adjusted
using the “LOCKON” menu.
Once the actual weight is displayed, the scale “Locks-On” to the
displayed. Weight does not change, even if the motion never stops. A
small ‘L’ appears on the left side of the display indicating the weight is
“Locked-On.” The animal’s weight must be greater than 2.5% of the
scales “capacity” weight before the system can “Lock-On.”
In order to break the lock, 50% of the displayed weight must be either
added or removed from the scale. The “Locked-On” weight can be
“rechecked” by pressing [ZERO] on the front panel. This breaks the
“lock” and the scale recalculates the weight.
NOTES: Setting the Weigh Method in the Long Form does not affect
the Display Unit LB-KG.
In Weigh Method #1, #2 and #3 the ZTRACK (zero-
tracking) removes up to 0.05% of the scale capacity (as
shown in setup). In Weigh Method #4, the weight that can
be removed is set to 5lbs(2.2kg).