Stockweigh 600 – Digi-Star StockWeigh 600 User Manual
Page 24
StockWeigh 600
20
.
+
+
&
A 00000 0 982 000017383201,<cr><lf>
890,LB,$,GR,8/27/03,10:15,_<cr><lf>
A 00000 0 982 000017383201,<cr><lf>
1001,LB, ,GR,8/27/03,10:21,M<cr><lf>
EID Print Data Format always uses date format #2 and 24-hour time
format as shown.
+
PRTFMT is active when “LSTORE” is set to “OFF”, “MANPRT” or
“AUTPRT”. Following is a detailed explanation of the print formats that
are available on the StockWeigh 600. Some are Comma Separated
Values (CSV) that make it easier to input scale data into PC
Spreadsheet and Data Base programs.
NOTE: The appearance of the printouts may be affected by the option
settings of 1L PRT, TIME F and DATE F.
AUTO
If “LSTORE” is set to “MANPRT” or “AUTPRT” and
“PRTFMT” is set to “AUTO”, the standard EZ Indicator
print format will be used.
Print example:
09MR04 10:15
880LB$GR
WTONLY
Includes weight, display unit, $' if unit is "locked on",
weight tag (GR, M+, etc.).
Ends with a
<CR>,<LF>.
Print example:
635LB$GR
DOWNLD
This format is compatible with the original Downloader.
Includes weight, display unit, $' if unit is "locked on",
weight tag (GR, M+, etc.) date and time.
DT+TM
This CSV format includes weight, display unit, $' if unit is
"locked on", weight tag (GR, M+, etc...) and date.