Stockweigh 600 – Digi-Star StockWeigh 600 User Manual

Page 16

Advertising
background image

StockWeigh 600

12

+

The Short Form Setup & Calibration procedure allows you to change

the “SETUP” and “CAL” numbers of the indicator. You may want to

perform this procedure if the indicator is being connected to different

load cells or if the scale is inaccurate and you have some accurate

known weights to use for calibrating the scale.

1. Press and hold [ZERO] and press [On/Off] for 3 seconds to

enter the short form calibration. The display will flash “SETUP”

and then display the 6-digit setup number with the right digit

flashing. To modify the setup number:

2. Press [GROSS/NET] several times to increment the digit to it

proper value.

3. Press [TARE] to advance the blinking digit to the left.
4. Repeat steps 1 and 2 for each digit as required.
5. Press [On/Off] to enter the new setup number and display the

calibration number.

6. Repeat steps 1 and 2 to modify the calibration number.
7. Press [On/Off] to enter the new calibration number and the

display will go back to normal.

8. Verify the accuracy of the scale and the procedure is complete!

Advertising