Stockweigh 600 – Digi-Star StockWeigh 600 User Manual
Page 16
StockWeigh 600
12
+
The Short Form Setup & Calibration procedure allows you to change
the “SETUP” and “CAL” numbers of the indicator. You may want to
perform this procedure if the indicator is being connected to different
load cells or if the scale is inaccurate and you have some accurate
known weights to use for calibrating the scale.
1. Press and hold [ZERO] and press [On/Off] for 3 seconds to
enter the short form calibration. The display will flash “SETUP”
and then display the 6-digit setup number with the right digit
flashing. To modify the setup number:
2. Press [GROSS/NET] several times to increment the digit to it
proper value.
3. Press [TARE] to advance the blinking digit to the left.
4. Repeat steps 1 and 2 for each digit as required.
5. Press [On/Off] to enter the new setup number and display the
calibration number.
6. Repeat steps 1 and 2 to modify the calibration number.
7. Press [On/Off] to enter the new calibration number and the
display will go back to normal.
8. Verify the accuracy of the scale and the procedure is complete!