10 . sy ste m but ton – Kawai MP6 User Manual

Page 61

Advertising
background image

61

1

0

. SY

STE

M But

ton

10.2.8 Local Control

On

The keyboard of the MP6 and the internal tone generators are

connected. Set this parameter to “On” for normal use.

Off

The internal connection between the keyboard and the tone

generators is switched off. This feature will avoid the “Doubled

Sound” that results from use with an external sequencer equipped

with Soft Thru or Echo Thru.

10.2.9 Program Change Mode

This parameter determines the sound numbering format that is used when
sending MIDI Program Change information.

Panel

Program Change data is sent in accordance with the instrument’s

panel button numbering format.

GM

Program Change data is sent in accordance with the standard GM

numbering format.

Select this setting when connecting the MP6 to GM devices.

10.2.10 MIDI Receive Mode

This parameter determines how the MP6 receives MIDI information.

Panel

Only MIDI information received from the designated system

channel will be sent to Zone 1-4 (Int. only).

With this setting, layer and internal effects will be available.

Multi

MIDI information received from all MIDI channels (1-16) will be sent

to Zone 1-4 or MIDI channels.

With this setting, the MIDI Receive Ch. (10.2.11) can also be specified.

Omni

Received data controls the whole panel, regardless of the MIDI

channel.

SYSTEM

Local

= On

SYSTEM

Local

= On

SYSTEM

Prg Mode =Panel

SYSTEM

Prg Mode =Panel

SYSTEM

Rcv Mode =Panel

SYSTEM

Rcv Mode =Panel

Advertising