15

TROUBLE

POSSIBLE CAUSE

REMEDY

4. Corner of crown distorted or

fractured

1. Excessive compression

2. Broken driver bar end

3. Worn bender bar

4. Clincher improperly aligned

or worn

5. Incorrect wire size

"A,B" Page 20

"I" Page 23

"G" Page 22

"C,F" Page 20,22

"N" Page 26

5. Stitch crown not flat and legs

not bent into work

1. Insufficient compression

"A,B" Page 20

6. One or both legs turn out

1. Clincher improperly aligned

2. Dull cutters

7. Flat piece of wire

"O" Page 26,27

"P" Page 27

"O" Page 26,27

"O" page 26,27

8. Stitches come out in pieces

"O" Page 26,27

"O" Page 26,27

"P" Page 27

"N" Page 26

"G,I" Page 22,23

9. Both stitcher legs are either

too long or too short

See "Changing Work

Thichness" Page 12

"F" Page 22

"L" Page 25

1. Rotator is dirty

2. Improperly adjusted lower wire

straightener

3. Broken or worn rotator

4. Improperly aligned rotator

Face plate not adjusted properly

1. Improperly aligned rotator

2. Weak rotator operating spring

3. Improperly adjusted upper wire

straightener

4. Incorrect wire size

5. Wire jammed in bender bar

grooves

M2000 Head Trouble Shooting