18

TROUBLE

POSSIBLE CAUSE

REMEDY

Stitcher drive does not operate

when foot switch is depressed

Safety Switch is not being

depressed by front guard

Adjust front guard and/or safety

switch bracket

Circuit breaker is blown

Press in the extended circuit

breaker. NOTE: If recently

blown, wait 10 min. before

pressing in.

Faulty foot switch (pressing foot

switch should break contacts of

switch inside Footswitch

assembly)

Replace footswitch

Faulty electrical connections

Use electrical schematic page

42, 43 to check wiring

Faulty safety switch

Replace switch

Faulty motor (test using 90 vdc)

Replace motor

Faulty circuit board

Replace circuit board

Stitcher keeps cycling, without

depressing footswitch or work

trip, until power is shut off

Faulty cam switch

Faulty electrical connections

replace switch

Use electrical schematic page

42, 43 to check wiring

Drive Trouble Shooting