Recessed installation, Installation, Picture of non combustible header – Montigo R320 User Manual

Page 13

Advertising
background image

Picture of Non combustible Header

Recessed Installation:

This fireplace can be recessed into the floor to get the viewing area as low as possible.
Maintain a minimum of 6" clearance from the bottom of glass to completed floor. Minimum clearance can be reduced to 3" for uncarpeted

flooring. Discolouration may occur due to high temperatures.

Figure 6. Recessed Fireplace installation

6” clearance

1” clearance

Recessed Floor

Steel header
(supplied by Montigo)

2-pcs 2 x 4 (vertical)
Both Sides Typ.

1” clearance

1” clearance

2 x 4

(horizontal)

2 x 4

(Vertical)

1” clearance

1” clearance

2 x 4

(horizontal )

Note: Images are shown without screens for clarity purposes.

However, your fireplace should not be operated without proper

installation of screens.

R320 & R420 Power Vent Indoor Gas Fireplace

Page 13

XG0770 - 150105.1

Installation

Advertising