Figure 8. Factory installed Top Vent Pressure Sensing Tube

Figure 8a. Supplied Rear Vent Pressure Sensing Tube

Figure 9. Removal of Top Vent air baffle and pressure sensing tube.

Figure 9a. Removal of Top Vent air baffle and pressure sensing tube.

NOTE: Rear vent pressure sensing tube is shipped inside the control box.

R320 & R420 Power Vent Indoor Gas Fireplace

Page 15

XG0770 - 150105.1

Installation

Section 3-1-2: Converting the Pressure Sensing

Tube and Air Baffle

When the

R320*/R420* is converted from Top Vent to Rear Vent,

the pressure sensing tube must be removed and replaced with

supplied Rear Vent pressure sensing tube and air baffle must be

relocated as described below.

1. Remove two screws from the air baffle installed over the Top

Vent from inside the firebox. Once air baffle is removed, replace

the two screws back into the same position.
Note: Not all models are equipped with an air baffle. Only convert

if available.
2. Remove Top Vent pressure sensing tube but loosening the

compression nut with a 1/2" wrench.

3. Position the supplied Rear Vent pressure sensing tube as

4. Install air baffle over Rear Vent from inside the firebox with two

screws provided at the Rear Vent.

shown in

Figure 9a. Hand tighten the compression nut by

hand and then a half-turn with a wrench.

Do not over tighten.