Figure 15a. (Control Panel Overview)

Figure 15b. R320 / R420 Control Module

Left-side View

Right-side View

Figure 15c.

(Remote Switch Wire connection)

Wall Switch

Installing the Remote Switch

The

R320 / R420 may be connected to a wall switch. The system

operates on a 24V AC.

DO NOT connect this circuit to an external

power source.

The power cord from the power vent module plugs into the side of

this panel. The 20 foot low voltage wire is attached and connected

to this panel as well. Connect a single pole On/Off switch (Black and

White) to these two wires at a location of your choice, (See Installing

the Remote Switch).
Montigo supplies 20' of low voltage wire to the electrical control panel.

Connect the two wire harnesses to a standard single pole ON/OFF

switch to the location of your choice. You may extend these wires

up to 100' in length with a wire of equal quality.
Installations in Canada must be electrically grounded in accordance

with

CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.

Installations in the USA must be electrically grounded in accordance

with local codes or, in the absence of local codes, with the National

Electrical Code,

ANSI/NFPA 70.

Installation of Electrical Supply

The

R320 / R420 is supplied with an external electrical control

panel pre-wired by the factory. The control box is connected to the

fireplace with a 20 foot long control cable that will communicate with

the fireplace. The control panel should be located where it can be

accessed when the fireplace has been finished in.

Power Vent

Harness

LED Indicator

Fuse

115V

Power Supply

Wall Switch Control

cable

115V

Outlet

Power Vent

Speed Control

Post Purge

Timer (3 min.)

Prepurge

Timer (1 min.)

Power

Vent Fuse

(5A)

Power Vent

Connector

Control

Panel Fuse

(5A)

LED

Power

Indicator

Heat Sensor /

Conmustion Switch

NOTE: Ensure that you maintain a 1" clearance around the box.