R320 & R420 Power Vent Indoor Gas Fireplace

Page 35

XG0770 - 150105.1

Appendix

PVVEX58-300 Power Vent Locations

v

v

FIXE

D

CLO

SED

OPE

RAB

LE

F

C

B

v

v

OPE

RAB

LE

FIXE

D

CLO

SED

v

B

X

B

A

B

J

H

I

X

K

v

M

V

B

L

D

E

V

INSI

DE

CORNE

R DE

TAIL

v

G

A

V

VENTER TERMINAL

X

AIR SUPPLY INLET

AREA WHERE TERMINAL IS

NOT PERMITTED

PVVEX58-300

A= Clearance above grade, veranda,

porch, deck, or balcony

12 in (30 cm)

12 in (30 cm)

Canadian Installations

US Installations

1

2

B= Clearance to window or door that
may be opened

6 in (15 cm) for appliances <

10,000 Btuh (3 kW), 12 in

(30 cm) for appliances >

10,000 Btuh (3 kW) and <
100,000 Btuh (30 kW), 36 in

(91 cm) for appliances >

100,000 Btuh (30 kW)

6 in (15 cm) for appliances <

10,000 Btuh (3 kW), 9 in

(23 cm) for appliances >

10,000 Btuh (3 kW) and <

50,000 Btuh (15 kW), 12 in
(30 cm) for appliances >
50,000 Btuh (15 kW)

C= Clearance to permently closed

window

B

B

N/A

D= Vertical clearance to ventilated
soffit located above the terminal within
a horizontal distance of 2 feet (61 cm)

from the center line of the terminal

N/A

E= Clearance to unventilated soffit

*

*

F= Clearance to outside corner

*

*

G= Clearance to inside corner

*

*

H= Clearance to each side of center
line extended above meter/regulator
assembly

3 ft (91 cm) within a height 15
ft. (4.5 m) above the meter/
regulator assembly

*

I= Clearance to service regulator

vent outlet

3 ft (91 cm)

*

J= Clearance to nonmechanical air
supply inlet to building or the
combustion air inlet to any other
appliance

6in (15 cm) for appliances <

10,000 Btuh (3 kW), 12 in (30

cm) for appliances > 10,000
Btuh (3 kW) and < 100,000
Btuh (30 kW), 36 in (91 cm)
for appliances > 100,000
Btuh (30 kW)

Canadian Installations

US Installations

1

2

6in (15 cm) for appliances <

10,000 Btuh (3 kW), 9 in (23

cm) for appliances > 10,000
Btuh (3 kW) and < 50,000
Btuh (15 kW), 12 in (30 cm)
for appliances > 50,000 Btuh
(15 kW)

K= Clearance to a mechanical air
supply inlet

6 ft (1.83 m)

3 ft (91 cm) above if within 10
ft (3 m) horizontally

L= Clearance above paved sidewalk
or paved driveway located on
public property

7 ft (2.13 m)

*

M= Clearance under veranda porch
deck, or balcony

12 in (30 cm)

*

1 In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code

2 In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two
single family dwellings and serves both dwellings.
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath
the floor.
* For clearances not specified in ANSI Z223.1/NFPA or CSA B149.1, one of the following shall be
indicated
a) A minimum clearance value determined by testing in accordance with section 2.23.5, or;
b) A reference to the following footnote:
"Clearance in accordance with local installation codes and the requirements of the gas supplier"

Figure 24c. PVVEX58-300 Power Vent Locations

Appendix A: Power Vent Locations