Installation and repairs should be done by an authorized gas fireplace service technician.

The appliance should be inspected before use and at least annually by a professional. More

frequent cleaning may be required due to excessive lint from carpeting, bedding material,

etc. It is imperative that control compartments, burners and circulating air passageways of

the fireplace are kept clean.

NOTICE

IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The

R320* & R420* Power Vent fireplaces must be installed

in accordance with these Instructions. Carefully read all the

instructions in this manual first. Consult the Local Gas Branch to

determine the need for a permit prior to starting the installation.

It is the responsibility of the installer to ensure this fireplace is

installed in compliance with the manufacturers instructions and

all applicable codes.

BEFORE YOU START:

Installation Checklist

■ Determine the desired install location of your fireplace.

■ See Section 1, Dimensions and refer to the Framing

Section 2 for details.

■ Select your type and location of your Power Vent

run: Roof Mounted (PVVEX58-300), External Wall

Mounted (PVHEX58-300), Flush Louver Wall Mounted

(PVHFL58-300). Inline Power Vent (PVHIN58-300) with

flush louvered termination (TMHIN58-40).

■ Your termination location should be selected to provide

the most efficient vent run.

■ Lay out the Vent run; calculating the required elbows

and straight runs of 5"/8" flex and/or rigid pipe.

■ Refer to the Section 3, "Venting" for details.

■ Montigo supplies 20' of low voltage wire, which can be

spliced to a maximum of 100' with wire of equal quality.

This wire CANNOT run in conduit with any other wire.

■ Refer to Section 4, for Wiring Details.

■ The gas connection is located on the bottom right side

(pilot burner side) of the fireplace.

■ Refer to local codes and guidelines for installation

requirements.

■ Refer to Section 5, "Installing the Gas Line" for details.

■ Installation and repairs should be done by a qualified

contractor and must conform to:

Installations in Canada must conform to the local

codes or in the absence of local codes to the current version

of Natural Gas and Propane Installation Code, CSA B149.

Electrical Installations must conform to the local codes or, in

the absence of local codes, to the current version of Canadian

Electrical Code, CSA C22.1.1

Installations in the USA must conform to the local

codes or in the absence of local codes to the current version

of National Fuel Gas Code, ANSI Z223.1/NFPA 54. Electrical

Installations must conform to the local codes or, in the absence

of local codes, to the current version of the National Electrical

Code, ANSI/NFPA 70. See

Appendix C for installation within

the State of Massachusetts.

Due to high operating temperatures, this appliance should be located out of traffic &

away from furniture and draperies.

Children and adults should be alerted to the hazards of the high surface temperature,

which could cause burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the

appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

CAUTION

When this appliance is installed directly on any combustible material other than wood

flooring, it must be installed on a metal or wood panel extending the full width and

depth of the appliance or a fire will occur causing serious injury, property damage or

even death.

DANGER

R320 & R420 Power Vent Indoor Gas Fireplace

Page 4

XG0770 - 150105.1

Section A: Before You Begin

Installation