Figure 12. Straight Horizontal, Top or Rear Vent, Wall mounted .............

power vent.

Figure 12b. Multi-Elbow, Top or Rear Vent, Wall mounted power vent.

Note: PVHIN58-300 cannot be installed closer than 7" feet to fireplace.

PVHIN58-300

Min. 7 feet of pipe between fireplace

and power vent

Figure 12a. PVHIN58-300 Power Vent

R320 & R420 Power Vent Indoor Gas Fireplace

Page 18

XG0770 - 150105.1

Installation

This section applies to installations where the shortest possible vent run is through the wall. Refer to

Appendix A - Power Vent locations,

to ensure the planned Power vent location is acceptable. Refer to the table below for vent run requirements.

Please note, images are shown

without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.

Section 3-3: Installing a Wall Mounted Vent System

Vent Configuration

Refer to Figure

Maximum Vent Run

(Horizontal + Vertical)

Maximum Elbows†

Straight Horizontal Top or Rear Vent

Figure 12

100 Feet

Six 90°

or

equivalent †

Multi-Elbow Top or Rear Vent

Figure 12a

Multi-Elbow with 6' downward vent

run Top or Rear Vent

Figure 12b

70 Feet**

† One 90° elbow is equal to two 45° elbows.

** For every additional 1 foot downward vent run subtract 10 feet from the maximum vent run.