Frame in the enclosure for the unit with framing materials, see Figure 3

.

NOTE: When constructing the framed opening, please ensure there is

access to install the gas line when the unit is installed.

See Figure 16.

Clearances:

To ensure the fireplace operates safely, all models must maintain

the following clearances:

R320*

24

24

2 6

3

0

See Section 7

Finishing around

the fireplace

R420*

24

24

2 6

3

0

MODEL

Top - Rear V

ent

Rear - T

op V

ent

Rear - Rear V

ent

Sides

Floor

Mantel

Top - T

op V

ent

Note: Clearance from top of fireplace to a combustible ceiling

within the fireplace enclosure.
Unprotected combustible walls which are perpendicular to the fireplace

opening must maintain 6" clearance, see

figure 20.

Figure 2. Clearances for rear vented installation with elbow.

Figure 2a. Clearances for top or rear vented installation, straight vent run or with

elbow(s).

Venting Clearance Requirements:

Wall framing

14” Min.

Wall framing

2” Min.

24" Min

Note: Images are shown without screens for clarity purposes.

However, your fireplace should not be operated without proper

installation of screens.

R320 & R420 Power Vent Indoor Gas Fireplace

Page 9

XG0770 - 150105.1

Installation

Section 2: Framing