Section 3-2-1: venting layout, Section 3-2: installing a roof mounted direct vent, Termination (pvtk-1) for 5"/8 – Montigo P52DF User Manual

Page 10: Installation

Advertising
background image

Page 10

P52DF* Indoor Gas Fireplace

XG0196 - 150204.3

Installation

Figure 8. (5"/8") Top vent, Roof mounted termination

with no offset in vent run.

Figure 8a. (5"/8") Top vent, Roof mounted with 1 offset

(1 offset= two 90° bends).

Figure 8b. (5"/8") Top vent, Roof mounted with 2 offsets

(1 offset= two 90° bends).

Roof mounted Terminations
The following details are some possible configurations for

Roof mounted terminations.

Section 3-2: Installing a Roof Mounted

Direct Vent Termination (PVTK-1) for 5"/8"

This section applies to installations where the direct vent termination

will be roof mounted.

Section 3-2-1: Venting Layout

Selection of components and details of venting lay out should adhere to

the following guidelines:

„

The maximum termination point is 32’ above the fireplace

(NOTE: if the maximum termination height is used, the

flame pattern may be affected).

„

The Vertical termination must be a minimum 2’ higher than

where the termination exits the roofing materials, (asphalt

shingles, cedar shakes, etc). This distance should be

measured from the high side of the roof slope where the

flue flashing intersects the roofing materials. (see

Figures

8 to 8c).

„

Termination location must be a minimum 6’ from a

mechanical air inlet.

„

For a more detailed diagram of allowed termination

locations, see

Appendix A.

„

A maximum of two offsets (each offset is made up of 2-90°

bends) may be made for vertical vent runs.

„

Firestops must be installed as required by National &

local codes

„

Ensure all horizontal runs are supported with a minimum

of 3 supports per 10’ of venting.

„

Install all roof flashing and storm collars as shown.

Support ring

Support plate

Firestop

32’ max.

2’ min.

Obstacle

PVTK1

Termination

8’ min.

Support straps or

support plate & rin

2’ min.

Firestop

Firestop

Firestop

32’ max

Support plate

& ring

Obstacle

PVTK1

Termination

8’ min.

Support ring

Support plate

Firestop

32’ max.

2’ min.

PVTK1

Termination

8’ min.

PEXT

PXT-10

Adaptor

Flue

Collar