Replacing light bulbs, Troubleshooting, Maintenance – Montigo P52DF User Manual

Page 29

Advertising
background image

Page 29

P52DF* Indoor Gas Fireplace

XG0196 - 150204.3

Maintenance

Figure 27. Remove the up-lighting glass from the burner tray.

The

P52DF* light bulbs can be replaced in a few simple

steps. Follow the directions for removing the door on

page

20. Once the door has successfully been removed, proceed

with

figures 27 - 27b.

Figure 27a. Wear gloves when handling light bulbs. To

remove a light bulb, pull connecting wire away from bulb

and pull light bulb up. Replace with new light bulb.

Figure 27b. Rotate newly replaced bulbs in a full circle.

Place glass cover back in the burner tray.

SIT Proflame 2:
The following is a troubleshooting chart of possible problems:

If your fireplace still does not operate correctly, consult

your local Montigo dealer.

All service and repairs should be performed by a

qualified Technician.

All spare parts, optional fans, and optional trim finishes

are available from your local Montigo dealer.

PROBLEM

SOLUTION

Pilot Igniter won't

spark

1. Check the MAIN ON-OFF

switch (typically located below

the valve cover) and turn ON
2. Ensure main power is ON

or new batteries are installed in

the remote control and backup

battery pack (if available).
3. Check the 3.15A fuse in

the control box and replace if

necessary

Pilot Igniter sparking,

but Pilot burner will

not light

1. Verify the Inlet and Manifold

Gas Pressure are within

acceptable limits
2. Check all connections to gas

valve
3. Check connection to stepper

motor (if available)

Pilot lights , but Main

burner will not Light

1. Check and verify all wiring

connections as per the wiring

diagram.
2 . Verify the inlet and Manifold

Pressure are within acceptable

limits

Pilot lights , but Main

burner will not Light

and igniter continues

to spark

1. Check the Pilot Flame Sensor

Rod and clean with steel wool

or similar.
2 . Check the Pilot hood and

clean with steel wool if dirty.
3. Adjust pilot flame using the

pilot adjustment screw if the pilot

flame is too long or too short

(Flame should fully engulf the

sensor rod and must be stable).
4. Check and make sure the

ground wire from the pilot is

connected to the fireplace body.

Fans not working

1. Ensure main power is ON

(fireplace may be operating on

back up batteries).
2. Check the 3.15A fuse in

the control box and replace if

necessary

One or more light bulbs

are not working

- Contact the local dealer for

repairs or service

Replacing Light Bulbs

Troubleshooting:

Advertising