Installation – Montigo P52DF User Manual

Page 14

Advertising
background image

Page 14

P52DF* Indoor Gas Fireplace

XG0196 - 150204.3

Installation

20”

56”

A

C

B

Unacceptable vent run

within shaded area.

Acceptable vent run

within non-shaded area.

If your installation does not fall

within the venting graph parame-

ters, please contact a local Montigo

Dealer for Power Venting options.

Notes Wall Mounted Terminations: 5"/10" Top & Rear Vent

■ All dimension lengths for vertical or horizontal runs

are measured from center of the vent pipe.

■ Venting runs must fall within the limits set by the

venting graphs, see

Figure 12.

■ Fireplace must be converted to Rear Vent configuration

prior to running vent, see Figure 7 and 7a.

The Venting Graph
Measure the vertical height from the fireplace hearth to the

centre of the termination and the horizontal run from the

fireplace flue collar to the wall flange of the termination. Plot

on the Venting Graph

Figure 12 with an 'X'.

If the 'X' falls on or above the top boundary of the shaded

area, the installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the

horizontal run to the wall flange of the vent termination is

138", this would be an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 48" and the

horizontal run to the wall flange of the vent termination is

72",

this would not be an acceptable installation.

Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is

60" and the horizontal run to the wall flange of the vent

termination is 144",

this would not be an acceptable

installation.

Figure 12. 5"/10" Top or Rear Vent Venting Graph for wall mounted

terminations.

Figure 12a. 5"/10"Top Vented, wall mounted installation with one

90° bend. The vent run must comply with Venting Graph for Top
vent, wall mounted terminations, Figure 12

.

Figure 12b. 5"/10" Rear Vented, wall mounted Multi-elbow

termination installation. The vent run must comply with the Venting

Graph for Rear vent, wall mounted terminations, Figure 12.

8” Max.

56”

Min.

12”

Max.

Flex or Rigid

Section

27”

Min.

28 3/4”

Heat Shield

Termination

Hearth

Exterior

Wall

Flex section

20” Max. for min Vertical

56” Min.

Note: Images are shown without screens for clarity

purposes. However, your fireplace should not be operated

without proper installation of screens.

Note: If power venting, vent run must be reduced to 5"/8"

or 4"/7". contact your Montigo dealer to discuss power

venting options.