Section 3-5: heat shields, Installation – Montigo P52DF User Manual

Page 17

Advertising
background image

Page 17

P52DF* Indoor Gas Fireplace

XG0196 - 150204.3

Installation

Section 3-5: Heat Shields

Installing a Wall Mounted RHS 102 Heat shield

The RHS102 Heat Shield (

Figure 16 and 16a) MUST be

used in all cases where the venting passes through a wall.
To install the RHS 102, frame an opening in combustible

construction. Slide the Heat shield in place over the vent

pipe which attaches to the fireplace. After the fireplace and

vent pipe has been installed, clearances should match the

dimensions in

Figure 14.

Figure 14. RHS102 Installation.

Installing a Wall Mounted RHS 104 Heat shield.

The RHS104 Heat shield

MUST be used in conjunction with

the RTO-4 Termination (

Figure 16 and 16a).

To install the RHS104, Slide the Inner Section over the vent

pipe. From the outside slide the RHS104 outer section on

(see

Figure 15a). To complete the installation fasten the Heat

Shield Outer Section & Termination frame to the structure.

Figure 16. RHS 102 & RHS 104 Installation. (Minimum

requirements).

Combustible

framing

Termination

Drywall / sheetrock

Outer Section

Vent pipe

RHS 104 Heat Shield

RHS 104 Heat Shield

Inner Section

Figure 16a. RHS 102 & RHS 104 Installation. (Minimum

requirements).

Figure 15a. RHS104 Installation.

RHS104 Heat

Shield

27” Min.

RTO-4Termination

36” Min

RHS 102

Heat

Sheild

60 Min”

5”/10”

Figure 14a. RHS102 Installation.

RHS 104 Heat Shield

RTO - 4 Termination

27” Min

RHS 102

Heat Shield

36” Min

60” Min

5”/10”

Figure 15. RHS104 Installation.

Combustible

framing

Drywall / sheetrock

Outer Section

Vent pipe

RHS 102 Heat Shield

RHS 102 Heat Shield

Inner Section

Outer Shield 10 5/8”

1/4” Min. Both sides Typical

1/4” Min.

1/4” Min .

Combustible Framing

Inner Shield 11 1/2”

Outer Shield 10 5/8”

1 1/4”” Min. Both sides Typical

1 1/4” Min.

1 1/4” Min.

Combustible Framing

Inner Shield 11 1/2”

Note: Images are shown without screens for clarity

purposes. However, your fireplace should not be operated

without proper installation of screens.