Section 2: framing & clearances, Installation, P52df* indoor gas fireplace – Montigo P52DF User Manual

Page 7: Rear vent

Advertising
background image

Page 7

P52DF* Indoor Gas Fireplace

XG0196 - 150204.3

Installation

Section 2: Framing & Clearances

Figure 2. Framing dimensions

(Straight wall & Corner Installation).
NOTE: Non-combustible header must be installed after unit

installation and before the installation of .nailing flange.

Figure 5. Non Combustible Framing for Top Vent or Rear

Vent, with alcove.

Figure 3. Combustible Framing for shelves over the

fireplace, Rear vent.

98

1" clearance

to corners only

5

2”

69 1/4”

84”

Min.

Header

MIN

1”

Alcove

area over

Fireplace

Top

Vent

Non-Combustible

Materials Only

Ceiling

37½”

Frame in the enclosure for the unit with framing materials.

The framed opening for the assembled fireplace is 52" wide,

x 43" high x 24 1/2" deep, see

Figure 2

.

NOTE: When constructing the framed opening, please

ensure there is access to install the gas line when the

unit is installed. See Figure 21.

Figure 4. Combustible Framing for shelves over the

fireplace, Top vent.

24 1/

2”

52 ”

43”

Noncombustible

Stud

37½”

Note: When sheetrock is not used behind

the fireplace, framing depth 24 1/2" may

be reduced by 5/8".

12”

Combustible Header

shelf

Rear Vent

43”

Non-combustible Header

Top Vent

56” Min.

26” Min

43”

1”

Non-

combustible

Header

Combustible Header

1”

7”

20” Max

Heat Sheild

6 1/2”

Note: Images are shown without screens for clarity

purposes. However, your fireplace should not be operated

without proper installation of screens.