P52DF* Indoor Gas Fireplace

XG0196 - 150204.3

Installation

Section 3-4: Venting Components

Connection and installation of the vent components should

adhere to the following guidelines:

„

Montigo recommends the use of a flex section for the

final pipe connected directly to the fireplace offering

greater flexibility of installation and absorption of

movement.

„

Firestops must be installed as required by National

& local codes

.

„

Montigo recommends that all exterior corners and

joints be sealed with exterior caulking. However, we

encourage you to consult your Building Envelope

Engineer or Waterproofing Consultant for further

recommendations.

„

Use any combination of rigid and flex pipe as required

and in any orientation (Male connectors can face in

any direction).

„

Flex sections may be stretched up to 50% of their total

length (e.g. a 24” section maybe stretched to 36”).

„

Connect all vent sections using a minimum of three

sheet metal screws on the outer pipe flue.

„

Ensure the pipe ends male to female slide in a

minimum of 1 1/2” of overlap.

„

Ensure all horizontal runs are supported with a

minimum of 3 supports per 10’ of venting.

„

When hanging/ supporting venting, ensure that 1”

clearance is maintained on sides and bottom of

vent runs and 2” above horizontal vent runs to any

combustible material.

„

Rigid pipe may be cut less than half way from the

female end only.

„

Ensure when cutting sections of rigid pipe to maintain

integrity of internal supports.

„

Place the springs, supplied with the pipe kit, between

the outer and inner pipes to keep the pipes separate

and avoid any possible hot spots.

IMPORTANT:

Please Refer to your Building Envelope

Engineer or Waterproofing Consultant

for a review of ALL penetrations through

exterior walls or the roof.

A - Termination

RTO4F

PVTK1SS

B - Frame Kits

MSR (Stucco Frame)

MOSR (Stucco Frame)

BSR-4 (4" Brick Frame)

BSR-6 (6" Brick Frame)

C - Flex Sections

PFL - 1 (12" f/f Section)

PFL - 18 (18" f/f Section)

PFL - 2 (24" f/f Section)

PFL - 3 (36" f/f Section)

PFL - 4 (48" f/f Section)

PFL - 6 (72" f/f Section)

D - Rigid Sections

PXT - 5 (5" f/f Section)

PXT - 10 (10" f/f Section)

PXT - 20 (20" f/f Section)

PEXT - 1 (12" f/m Section)

PEXT - 2 (24" f/m Section)

PEXT - 3 (36" f/m Section)

PEXT - 4 (48" f/m Section)

PEXT - 6 (72" f/m Section)

RXT - 10 (10" f/f Section)

RXT - 20 (20" f/f Section)

REXT - 1 (12" f/m Section)

REXT - 2 (24" f/m Section)

REXT - 3 (36" f/m Section)

REXT - 4 (48" f/m Section)

REXT - 6 (72" f/m Section)

E - Elbows

PEL-90MM (m/m 90º Elbow)

PEL-90FF ( f/f 90º Elbow)

PEL-90FM ( f/m 90º Elbow)

PEL-45FM ( f/m 45º Elbow)

REL-90MM (m/m 90º Elbow)

REL-90FF ( f/f 90º Elbow)

REL-90FM ( f/m 90º Elbow)

REL-45FM ( f/m 45º Elbow)

F - Support Ring & Plate PSPXT-8
G - Firestop

FS-8

H - Roof Flashing

PRF-7 (1/12 - 7/12 pt.)

PRF-12 (7/12 - 12/12 pt.)

I - Heat Shield

RHS101

RHS102

RHS104

J - Heat Guard

MTKOG

K - Reducing Collar

RC108

L - Through the Wall

Venting Kit

RFVKO1F