P52DF* Indoor Gas Fireplace

XG0196 - 150204.3

Installation

Figure 13. Corner installation.

Figure 13a. Flex installation.

45° Corner Installation.

Attach an REL-45 (45° elbow) directly onto the flue collar.

Cut the RXT-20 to suit, and attach it to the REL-45. Slide

the fireplace into position and attach to the termination.

45° or less Corner Installation.
Use an RTO-4 termination and an RFL-4 (48" compressed

length) and a frame, if appropriate.

Flex may be turned

to obtain desired degree of angle required but must not

exceed 45°.

Note: Through the wall venting kits are also available

for both the Straight and the Corner Installation. The

Kit includes a RHS 104 heat shield, a RFL-2(f/f) flexible

pipe, and a termination with or without a mounting frame.

Flue Collar

REXT - 1

REL - 90 Elbow

REL - 45 Elbow

RXT 20

104

RTO-4F

RFL4

RTO-4F

104

Note: For corner installation you need a minimum 56" from hearth to centre of pipe. Framing must be done as

described in Figure 2 on page 6.

Note: Images are shown without screens for clarity

purposes. However, your fireplace should not be operated

without proper installation of screens.