Appendix 1 – Factory Defaults

Universal Defaults

• Temperature in °F
• All Baud Rates initially 19200 and set for Modbus

• Burnoff time is 90 seconds

• Burnoff recovery wait time is 2 minutes

• Burnoff interval is 12 hours

• Burnoff maximum temperature is 2000 °F
• CO Factor is 200

• Hydrogen factor for Dewpoint calculation is 40%

• Analog to Digital Converter filter time is 8 seconds for all 3 ADCs

• For analog input 1 initial scale is 0, and full scale is 1000

• For analog input 2 initial scale is 0, and full scale is 10000

• For analog input 3 initial scale is 0, and full scale is 10000

• First Process Control Setpoint is set to 0

• First Process Proportional Band is 20%

• First Process Reset for PID control is On

• First Process Rate for PID control is 0

• First Process Output Cycle Time for Control is 16 milliseconds

• First Process Auto/Manual set to Automatic

• First Process Control Load Line or Manual Reset (integral preset) set to 0

• Second Process Control Setpoint is set to 0

• Second Process Proportional Band is 4.4%

• Second Process Reset for PID control is 12

• Second Process Rate for PID control is 216

• Second Process Output Cycle Time for Control is 60 milliseconds

• Second Process Auto/Manual set to Automatic

• Second Process Control Load Line or Manual Reset (integral preset) set to 0

• Start PV for temporary tuning set to 0

• Temporary Proportional band for tuning set to 2%

• Temporary reset for tuning set to On

• Temporary rate for tuning set to 0

• Temporary integral preset for tuning set to 0

• Relay 1 set for loop 2 heat

• Relay 2 set for alarm 1

• Relay 3 set for loop 1 increment (gas)

• Relay 4 set for loop 1 decrement (air)

• Relay 5 fixed by PV type.

• Relay 6 set for Probe Burnoff

• Relay 7 set for Alarm 3

• Relay 8 set for all alarms.

• Alarm 1 setpoint set for 1800

• Alarm 1 is set for analog input 2

• Alarm 1 hysteresis is set for 1

• Alarm 2 setpoint set for 2000

• Alarm 2 is set for analog input 1