Simple nitrider pvt defaults, Dual loop pvt defaults – Super Systems HP15 User Manual

Page 22

Advertising
background image

HP 15 Manual Rev A

Page 22 of 22

• Analog output 1 range is 200

• First process control low limit is –100

• First process control high limit is 100

• First process control mode is such that setpoint of 0 shuts down and it is in dual mode

• Second process control low limit is 0

• Second process control high limit is 100

• Second process control mode is such that it is in single reverse

• Analog input 1 full scale is 2500

• Analog input 2 full scale is 2500

• Analog input 1 type is 2.5 volts

• Analog input 2 type is 2.5 volts

• Analog input 3 type is K thermocouple

• 20 minutes delay time before alarm

• Band +/1 for alarm in millivolts is 10

• Modbus at 9600 baud

Simple Nitrider PVT Defaults

• Process variable 1 is carbon

• Process variable 2 is temperature

• Process variable 3 is temperature

• DAC 1 is set for Hydrogen

• DAC2 is set for Dissociation

• Analog output 1 offset is 0

• Analog output 1 range is 1000

• Analog output 1 offset is 0

• Analog output 1 range is 1000

• First process control low limit is –100

• First process control high limit is 100

• First process control mode is such that setpoint of 0 shuts down and it is in dual mode

• Second process control low limit is 0

• Second process control high limit is 100

• Second process control mode is such that it is in single reverse

• Analog input 1 full scale is 2500

• Analog input 1 type is 2.5 volts

• Analog input 2 type is S thermocouple

• Analog input 3 type is K thermocouple

• host RS232

• Hitech H2 cell at 9600 baud

Dual Loop PVT Defaults

• Alarm 2 setpoint is 2000

• Alarm 3 setpoint is 2000

• Alarm 2 type is input 1 process high

• Alarm 3 type is PV2 process high