Carbon pvt defaults, Dewpoint pvt defaults, Oxygen pvt defaults – Super Systems HP15 User Manual

Page 20

Advertising
background image

HP 15 Manual Rev A

Page 20 of 20

• Alarm 2 hysteresis is set for 1

• Alarm 3 setpoint set for 2000

• Alarm 3 is set for process variable 2

• Alarm 3 hysteresis is set for 1

• Digital to Analog converter 1 assignment is PV1 retransmit

• Digital to Analog converter 2 assignment is loop 2 increment

• Default IP is 192.168.0.200

Carbon PVT Defaults

• Process variable 1 is carbon

• Process variable 2 is temperature

• Process variable 3 is temperature

• Analog output 1 offset is 0

• Analog output 1 range is 2000

• Analog output 1 offset is 0

• Analog output 1 range is 2000

• First process control low limit is –100

• First process control high limit is 100

• First process control mode is such that setpoint of 0 shuts down and it is in dual mode

• Second process control low limit is 0

• Second process control high limit is 100

• Second process control mode is such a high analog input 2 shuts down

• Analog input 1 full scale is 2500

• Analog input 1 type is 2.5 volts

• Analog input 2 type is S thermocouple

• Analog input 3 type is K thermocouple

Dewpoint PVT Defaults

• Process variable 1 is dewpoint

• Process variable 2 is temperature

• Process variable 3 is temperature

• Analog output 1 offset is 0

• Analog output 1 range is 2000

• Analog output 1 offset is 0

• Analog output 1 range is 2000

• First process control low limit is –100

• First process control high limit is 100

• First process control mode is such that dual direct mode

• Second process control low limit is 0

• Second process control high limit is 100

• Second process control mode is such a high analog input 2 shuts down

• Analog input 1 full scale is 2500

• Analog input 1 type is 2.5 volts

• Analog input 2 type is S thermocouple

• Analog input 3 type is K thermocouple

Oxygen PVT Defaults

• Process variable 1 is carbon