TITLE: MODBUS/J-BUS Protocol for SSi’s- AC20 ENG. 824E REV. 1

INDEX, DIVIDED IN FAMILIES AND GROUPS, OF MODBUS WORDS

Words For Device In Control Mode - Parameters

Menu group 1 – Set point values

138 - Main set point

("SP")

page 18

139 - Auxiliary set point 2

(“SP2”)

page 18

140 - Auxiliary set point 3

(“SP3”)

page 18

141 - Auxiliary set point 4

(“SP4”)

page 18

142 - Carbon monoxide factor

("COF")

page 18

143 - Hydrogen factor

("H2F")

page 18

Menu group 3 - Alarm threshold and hysteresis value

177 - Alarm 1 threshold

("AL1")

page 18

178 - Alarm 2 threshold

("AL2")

page 18

179 - Alarm 3 threshold

("AL3")

page 18

181 - Band alarm 1 threshold low

("bA1.L")

page 18

182 - Band alarm 1 threshold high

("bA1.h")

page 18

183 - Band alarm 2 threshold low

("bA2.L")

page 18

184 - Band alarm 2 threshold high

("bA2.h")

page 18

185 - Band alarm 3 threshold low

("bA3.L")

page 18

186 - Band alarm 3 threshold high

("bA3.h")

page 18

191 - Alarm 1 hysteresis

("HSA1")

page 18

192 - Alarm 2 hysteresis

("HSA2")

page 18

193 - Alarm 3 hysteresis

("HSA3")

page 18

Menu group 4 - Control parameters

148 - Proportional band

("Pb")

page 19

149 - Hysteresis for on/off control mode

("HYS")

page 19

150 - Integral time

("ti")

page 19

151 - Derivative time

("td")

page 19

152 - Integral pre-load

("IP")

page 19

153 - Relative secondary output gain

("r.Gn")

page 19

154 - Dead band/overlap between main/secondary output

("OLAP")

page 19

Menu group 5 - Auxiliary control parameters

1000 - Anti-reset windup

("ArU")

page 20

1003 - Main control output low limit

("ñ.OLL")

page 20

1004 - Main control output high limit

("ñ.OLH")

page 20

1005 - Main control output max rate of rise

("ñ.rñP")

page 20

1006 - Proportional cycle time on main control output

("ñC.CY")

page 20

1007 - Secondary control output low limit

("S.OLL")

page 20

1008 - Secondary control output high limit

("S.OLH")

page 20

1009 - Secondary control output max rate of rise

("S.rñP")

page 20

1010 - Proportional cycle time on secondary control output

("SC.CY")

page 20

1011 - Set point low limit

("rL")

page 20

1012 - Set point high limit

("rH")

page 20

1013 - Rate of change for positive set point variation

("Grd1")

page 20

1014 - Rate of change for negative set point variation

("Grd2")

page 20

1016 - External control of auto/man function

("E.Añ")

page 20