TITLE: MODBUS/J-BUS Protocol for SSi’s- AC20 ENG. 824E REV. 1

300 - Decimal number relative to primary control variable

page 28

301 - Decimal number relative to main control output in engineering units

page 28

302 - Decimal number relative to secondary control output in eng. units

page 28

347 - Code for enable configuration mode

page 29

348 - Code for enable security code mode

page 29

349 - Code for lock/unlock control parameters

page 29

350 - Lock/unlock status group hidden

page 29

351 - Lock/unlock status group 1

page 29

352 - Lock/unlock status group 2

page 29

353 - Lock/unlock status group 3

page 30

354 - Lock/unlock status group 4

page 30

355 - Lock/unlock status group 5

page 30

356 - Lock/unlock status group 6

page 30

357 - Lock/unlock status group 7

page 30

358 - Lock/unlock status group 8

page 30

359 - Lock/unlock status group 9

page 30

526 - Serial interface protocol

("S.L.Pr")

page 23

527 - Serial link device address

("S.L.Ad")

page 23

528 - Baud rate for serial link

("S.L.bd")

page 23

529 - Byte format for serial link

("S.L.bF")

page 23

1000 - Anti-reset windup

("ArU")

page 20

1003 - Main control output low limit

("ñ.OLL")

page 20

1004 - Main control output high limit

("ñ.OLH")

page 20

1005 - Main control output max rate of rise

("ñ.rñP")

page 20

1006 - Proportional cycle time on main control output

("ñC.CY")

page 20

1007 - Secondary control output low limit

("S.OLL")

page 20

1008 - Secondary control output high limit

("S.OLH")

page 20

1009 - Secondary control output max rate of rise

("S.rñP")

page 20

1010 - Proportional cycle time on secondary control output

("SC.CY")

page 20

1011 - Set point low limit

("rL")

page 20

1012 - Set point high limit

("rH")

page 20

1013 - Rate of change for positive set point variation

("Grd1")

page 20

1014 - Rate of change for negative set point variation

("Grd2")

page 20

1016 - External control of auto/man function

("E.Añ")

page 20

1100 - Alarm 1 type

("A1.tP")

page 21

1101 - Alarm 1 configuration

("A1.Cn")

page 21

1102 - Alarm 1 action

("A1.Ac")

page 21

1103 - Alarm 1 standby function

("A1.St")

page 21

1104 - Alarm 2 type

("A2.tP")

page 21

1105 - Alarm 2 configuration

("A2.Cn")

page 21

1106 - Alarm 2 action

("A2.Ac")

page 21

1107 - Alarm 2 standby function

("A2.St")

page 21

1108 - Alarm 3 type

("A3.tP")

page 22

1109 - Alarm 3 configuration

("A3.Cn")

page 22

1110 - Alarm 3 action

("A3.Ac")

page 22

1111 - Alarm 3 standby function

("A3.St")

page 22

1200 - Min value of proportional band calculated by the smart algorithm (“Pb.Lo")

page 25

1201 - Max value of proportional band calculated by the smart algorithm ("Pb.Hi")

page 25

1202 - Min value of integral time value calculated by the smart algorithm ("ti.Lo")

page 25

1203 - Max value of integral time value calculated by the smart algorithm ("ti.Hi")

page 25

1204 - Relative secondary output gain calculation by the smart algorithm ("rG.CL")

page 25

1300 - Timer for burn-off

(“t.bOF”)

page 24

1301 - Timer for purge

(“t.PrG”)

page 24

1302 - Timer for automatic burn-off interval

(“bF.tr”)

page 24

1303 - Timer for probe test interval

(“Pb.tr”)

page 24

1304 - Time lasting to beginning of burn-off procedure

(“bF.ñn”)

page 24

1305 - Time lasting to beginning of probe test procedure

(“Pb. ñn”)

page 24