TITLE: MODBUS/J-BUS Protocol for SSi’s- AC20 ENG. 824E REV. 1

Menu conf. 3 - Control output configuration

2205 - Main control output conditioning

("ñC.Cn")

page 40

2206 - Main control output scaleable for display in e.u.

("ñ.SCL")

page 40

2207 - Decimal point position for main control output display in e.u.

("ñC.dP")

page 40

2208 - Low scale range value for main control output display in e.u.

("ñC.E.L")

page 40

2209 - High scale range value for main control output display in e.u.

("ñC.E.H")

page 40

2210 - Main control output auxiliary conditioning

("ñC.A.C")

page 40

2211 - Secondary control output conditioning

("SC.Cn")

page 40

2212 - Secondary control output scaleable for display in e.u.

("S.SCL")

page 40

2213 - Decimal point position for secondary control output display in e.u. ("SC.dP")

page 41

2214 - Low scale range value for secondary control output display in e. u. ("SC.E.L")

page 41

2215 - High scale range value for secondary control output display in e. u. ("SC.E.H")

page 41

2216 - Secondary control output auxiliary conditioning

("SC.A.C")

page 41

Menu conf. 4 - Auxiliary control output configuration

2300 - Smart function

("Sñ.Fn")

page 42

2301 - Control action type

(“Cn.Tp”)

page 42

2302 - Manual function

("ñAn.F")

page 42

2303 - Output value for transfer from auto to manual

("Añ.UL")

page 42

2304 - Manual/auto transfer type

("ñ.A.t.t")

page 42

2305 - Device status at start up

("St.Fn")

page 42

Menu conf. 5 - Digital input/output configuration

2400 - External contact "DIG1" function

("d1.Fn")

page 43

2401 - External contact "DIG1" logic level

("d1.St")

page 43

2402 - External contact "DIG2" function

("d2.Fn")

page 43

2403 - External contact "DIG2" logic level

("d2.St")

page 43

2405 - External contact "DIG3" logic level

("d3.St")

page 43

Menu conf. 6 - Other configuration parameters

2500 - Green bar-graph selection

("G.brG")

page 44

2501 - Orange bar-graph selection

("O.brG")

page 44

2502 - Bar-graph low scale range value

("brG.L")

page 44

2503 - Bar-graph high scale range value

("brG.H")

page 44

2504 - Deviation bar-graph resolution

("brG.d")

page 44

2506 - Set point display type

("SP.dS")

page 44

2507 - Temperature threshold activation

(“t.t.Ac”)

page 44

2509 - Time-out selection

("t.out")

page 44

Words For Device In Configuration Mode - Non Parameters

3000 - The end of configuration menu 1

page 45

3001 - The end of configuration menu 2

page 45

3002 - The end of configuration menu 3

page 45

3003 - The end of configuration menu 4

page 45

3004 - The end of configuration menu 5

page 45

3005 - The end of configuration menu 6

page 45

3050 - Load default configuration value

page 45

3051 - Enable control mode