2 units, 3 flow rate decimals – Tecfluid MX4 For FLOMAT Series User Manual

Page 34

Advertising
background image

34

7.2 Units

In this screen the units for the liquid velocity, the flow rate and the totalizer can be chosen
independently.

7.3

Flow rate decimals

In this screen the number of decimals for the flow rate indication can be selected.

To select the number of decimals it must be taken into account that the instrument has 5

digits for flow rate indication. If two decimals have been selected, these will be seen whilst
the flow rate is not higher than 999.99. Above this value the indication will automatically
change to one decimal, and when the flow rate is higher than 9999.9 the indication will be
done without decimals.

If one decimal is selected, the flow rate indication will have a maximum of one decimal

until 9999.9. Above this value the indication will be done without decimals.

If indication without decimals is selected, the flow rate will always be shown without

decimals.

For the selection of the flow rate units and the number of decimals it must be taken into

account that an indication with an excess of decimals may give the sensation of instability
of the reading. As a general rule it can be considered that the reading should not have
more than a total of 5 digits (integer + decimals).

7

INSTALLATION PARAMETERS

Advertising