WH2-605A.4

Problem

Possible cause

Solution

Vacuum line problem.
Disconnect the vacuum line at
the first vacuum hopper and
block it off. The vacuum here
should equal the vacuum at the
blower. Allow a few seconds for
vacuum to build. If the vacuum
here is low, disconnect the
piping halfway to the first
vacuum hopper and check the
vacuum there. If proper vacuum
exists, the problem is upstream.
If not, work backward to isolate
the vacuum loss.

Pump package blower problem.
Use a cfm/cfh monitoring device
to ensure that blower cfm/cfh is
to the manufacturer’s
specifications.

(Cont’d.)

• Tighten loose pipe couplers;

replace worn gaskets as
needed.

• Replace any damaged piping

found.

Vacuum conveying rate is
declining due to a vacuum loss
in the system.

(Cont’d.)

Leaks in vacuum lines between
valves.

Check for leaks as described in
previous steps.