VacTrac™ Series Conveying Systems

Page 81

Mechanical Components

WH2-605A.4

Note: To change motor rotation:

• Disconnect power at the external disconnect.
• Switch any two incoming power leads on the main

power supply.

;

Make sure that filter chamber housings have no leaks; check

stretcher clamps for tightness.

4-4 ACA Series Filter Chamber Operation

ACA Series Filter Chamber Pre-Operation Checklist

Check the following before you operate ACA Series filter
chambers:

;

Make sure all mechanical installations are complete.

;

Make sure all electrical and compressed air connections are

complete and correct.

;

Make sure that no leaks are present in the filter chamber

housing. Check stretcher clamps for tightness.

Adjusting Time Between Air Pulses

Models 91/93, 151/153, and 251/253

The time between cleaning air pulses requires adjusting to match
up with dusting characteristics of the material being conveyed. If
more dusting occurs, then more frequent compressed air pulses are
required to clean filter bags.

Locate the off-time control potentiometer inside the control
enclosure and adjust from 0- to 30-second intervals between air
pulses to match material conveying characteristics.

Adjusting Air Pulse Duration: All Models

Locate the on-time potentiometer inside the control enclosure on
the circuit board. With the unit operating, turn the potentiometer
counterclockwise to shorten the air pulse duration; turn clockwise
to lengthen
the air pulse.