VacTrac™ Series Conveying Systems

WH2-605A.4

Mechanical Components

4-3 Making Startup Checks

Before operating the VacTrac or any other part of the conveying
system, check these details:

;

All components in the system must be installed securely and

prepared for operation. Refer to the instructions supplied with
auxiliary equipment for specific checks.

;

Couplers, fittings, attachments, and flexible lines must be

attached securely and be vacuum-tight.

;

Electrical and compressed air connections to the pump

package, vacuum hoppers, and filter chambers must be
complete, safe, and conform to code.

;

The pump package blower gearbox must be filled with oil as

specified in the manufacturer’s instructions included in the
customer information package.

!

CAUTION

Do not overfill the blower gearbox with oil; too much oil damages the blower.

;

If not done already, remove the plastic plug from the silencer

air outlet.

!

WARNING

Keep hands away from the open air inlet to
avoid injury!

;

Do not allow any loose parts, tools, or foreign materials in or

near the unit and other system components.

;

Check for proper motor rotation, as indicated by an arrow on

the pump package motor. Bump-start the pump package with
the compressed air disconnected just long enough to verify
proper rotation direction.