Caution – AEC VacTrac Series Conveying Systems User Manual

Page 86

Advertising
background image

Page 86

VacTrac™ Series Conveying Systems

WH2-605A.4

Mechanical Components

• V-belts are sized for maximum life with the pump package

blower/motor combination. Inspect periodically for proper
tension, and replace when worn.

Important!

V-belts stretch when new. Check belt tension after you have run them in.

At proper belt tension, the belt should deflect downward

1

/

64

” for every one inch span (1 mm every 6.4 cm) from sheave to sheave.

• Keep the pump package area clear of any debris that could be

drawn through the vent valve and into the blower while the
pump package is idling.

• Torque the motor and blower sheave bolts to 72 ft.-lbs.

(98 Nym).

• Check the moisture traps in the compressed air lines. Drain

as needed.

• Check the compressed air lubricator(s) for flow rate and

level. Use only 1 or 2 drops of oil per day when lubricating.
Adjust and fill as necessary.

• Inspect the silencer periodically for contamination. Silencer

fouling indicates poor filter maintenance at the vacuum
hopper or filter chamber. Fines may also be drawn into the
silencer through the pump package vent valve during the
dump cycle from poor housekeeping near the pump package.

!

CAUTION

Make sure you replace a contaminated silencer immediately

to avoid blower damage and possible fire hazard.

• Standard pump package TEFC motors do not require

lubrication or oiling. Optional motors may have different
requirements. Refer to the motor manufacturer’s
specification sheet in your Customer Information Packet.

• Keep the control panel and pump package junction boxes

securely closed to prevent component contamination.