Important – AEC VacTrac Series Conveying Systems User Manual

Page 49

Advertising
background image

VacTrac™ Series Conveying Systems

Page 49

Mechanical Components

WH2-605A.4

A compressed air filter cleaning blow back option is available for
systems conveying very dusty materials. Consult the AEC Sales
Department for more information.

Level and secure the filter chamber near the pump package. Use

3

/

8

” (9 mm) bolts to anchor the filter chamber.

1.

Connect the piping between the vacuum inlet valve on the
pump package and the tube stub on the filter chamber lid.
For easy filter maintenance, install at least three feet (3’ /
1 m) of vinyl flex hose at the end of the run to the filter
chamber. The rest may be hard piping as long as it is
properly supported.

2.

Run vacuum tubing from the tangential inlet tube to the
vacuum header line servicing the vacuum hoppers. Turn the
inlet tube toward the header. Support the tubing properly
and make it vacuum-tight.

Important!

Use of a VacTrac system without an AEC -approved filter system

installed on the vacuum air inlet voids the blower warranty!