Isee drawing above – AEC FSS Series 1.5- 10 HP Fountain Solution Systems User Manual

Page 17

Advertising
background image

Page 16

FSS Series Fountain Solution Systems

IAE-600

Figure 4

FSS-R Remote Condenser Assembly Models

To convert inches to cm, multiply dimension by 2.54.

Fan(s) d e f

Remote Condenser

Refrigeration g

Each

Totals e f

Overall Dimensions

Connections

Charge

Model

Dia.

Motor

Amps

Air flow Net wt. Length Width Height

Mtg. Discharge Liquid

R-22

Number

in.

hp c

460V Fans

cfm h

lbs. h

‘A’(in.) ‘B’(in.) ‘C’(in.) ‘D’(in.) ODS(in.) ODS(in.) lbs. g

FSS-R5

¾ hp 1 ø

2.4

1

6,450

260

49.8

40.0

1⅛

3.6

FSS-R7.5

3.7

2

12,400

470

69.8

60.0

1⅛

3.6

FSS-R10

3.7

2

13,700

510

89.8

80.0

1⅜

1⅛

4.6

FSS-R15

26

⅓ hp 3 ø

5.0

3

20,500

550

129.8

43.0

40.5

120.0

1⅝

1⅛

6.4

FSS-R20

5.9

2

23,000

840

125.0

108.0

10.0

FSS-R25

5.9

2

21,900

860

125.0

108.0

1⅝

16.0

FSS-R30

9.4

3

34,800 1,280

180.0

24.0

FSS-R35

9.4

3

32,900 1,300

180.0

24.0

FSS-R40

30 1 ½ hp 3 ø

12.9

4

46,400 1,690

235.0

45.5

50.0

i

2⅛

29.0

c

ø represents electrical phase; all motors are 1,140 rpm. Multiply hp by 0.746 to convert to kW.

d

All first fan motors (Header Side) are ¾ hp (0.56 kW) single phase variable speed.

e

Multiply 460V amperages by 2.0 for 208-230V amperages.

f

Multiply 460 V amperages by 0.8 for 575 V amperages.

g

Refrigeration charge is for remote condenser only!

h

To convert cfm to cmh, multiply by 1.699. To convert lbs. to Kg, multiply by 0.454.

i

See drawing above.

Advertising