FSS Series Fountain Solution Systems

Page 53

IAE-600

7-4-3

9-second settings

1.) In the operational mode, press the SEL key for 9 seconds until

the display reads Pn-1.

2.) Press the up or down keys to scroll through the menu.
3.) To change the value of a parameter, go to the desired

parameter and press SEL.

4.) The value should appear, press the up or down key to change

the value.

5.) Press the SEL key to return to the menu.
6.) To return to operational mode, hold down the SEL key for 9

seconds.

PARAMETERS

DESCRIPTION

VALUE

Pn-1

Control Action Code

1

Pdf

Input Filter Constant

1.0

P-An

Alarm Hysteresis

5

rCJ

N/A

On

PLC-1

N/A

-3

PHC-1

N/A

103

PLC-2

N/A

-3

PHC-2

N/A

103

PCUT

N/A

0

FUZY

On/Off

OFF

GAIN

N/A

1

ADJO

Zero Calibration

0

ADJS

Span Calibration

0

OUT

N/A

103

dPS1

Parameter Mask 1

255

dPS2

Parameter Mask 2

255

dPS3

Parameter Mask 3

255

dPS4

Parameter Mask 4

255

dPS5

Parameter Mask 5

255

dPS6

Parameter Mask 6

255

dPS7

Parameter Mask 7

255