6 flowmeter, Tab. 6, Advanced setup – ARAG GCS 3200 User Manual

Page 20

Advertising
background image

20

12.6

Flowmeter

Fig. 34

Fig. 35

Flowmeter out of range

Rate alarm

Set the installed flowmeter by selecting it from the list (as indicated in Tab. 6).
The relevant configuration data will be loaded automatically and can be customized.

Type

:

indicate the type of installed flowmeter (Tab. 6).

Min. flowrate alarm

Max. flowrate alarm

The flowmeter rate alarms (minimum or maximum) activate when, during the treatment, the flowmeter rate does not respect the set limits.

For the procedure to be followed in case of alarms, please refer to Par. 16.1 - Operation errors.

Constant

: indicate the constant of the installed flowmeter.

When the option

None

is selected, the items

Min. flowrate alarm Max. flowrate alarm

and Constant

are not longer visible on

the display (Fig. 35).

orion flowMeters

TYPE

UNIT OF MEASUREMENT - METRIC

UNIT OF MEASUREMENT - US

The default values can be modified.

Constant

(pls/l)

Min. rate

(l/min)

Max. rate

(l/min)

Constant

(pls/gal)

Min. rate

GPM

Max. rate

GPM

4621xA0xxxx

6000

0,5

10,0

22710

0,13

2,60

4621xA1xxxx

3000

1,0

20,0

11355

0,30

5,00

4621xA2xxxx

1200

2,5

50,0

4520

0,60

13,00

4621xA3xxxx

600

5,0

100,0

2271

1,30

26,00

462xxA4xxxx

300

10,0

200,0

1135

2,60

53,00

4622xA5xxxx

150

20,0

400,0

568

5,00

106,00

4622xA6xxxx

100

30,0

600,0

370

8,00

158,00

Other...

625

10,0

100,0

2366

2,60

53,00

Tab. 6