2 source - wheel sensor, User setting – ARAG GCS 3200 User Manual

Page 27

Advertising
background image

27

13.1.2 Source - Wheel sensor

Fig. 54

Selected wheel type

: select the type of wheel (3 types available).

Wheels setting

: set the wheel constant (3 available).

The constant can be inserted with two different procedures (manual or automatic),
described below.

Constant calculation: Manual

It allows to enter the wheel constant value calculated with the suitable formula.

Take measurements with tyres at the operating pressure.

Kwheel =

distance traveled (cm)

no. of detection points x wheel RPM

<distance traveled> distance expressed in cm covered by the wheel along
measurement travel.
<no. of measurement points> number of measurement points (e.g. magnets, bolts,
etc.), mounted on wheel.
<no. of wheel revolutions> number of wheel revolutions required to travel
measurement distance.

The wheel constant can be calculated with a good approximation detecting the distance
traveled by
the wheel with the speed sensor.
(The longer the distance traveled, the more accurate the wheel constant calculation).

Select

Wheel constant

1

,

2

or

3

and enter the calculated value.

Constant calculation: Automatic

It allows to calculate and save the wheel constant with the formula below:

Fig. 55

Take measurements with tyres at the operating pressure.

This test must be performed on medium-hard terrain;
for application to very soft or very hard terrain, rolling diameter

may vary, leading to inaccurate output calculation; when this is the
case, repeat the procedure.
During the test, cover the distance with the tank filled up to half
capacity with water.

Fig. 56

- Measure a straight path at least 100 m (300 feet) long.:

Reference distance

(Fig. 56)

.

(The longer the distance traveled, the more accurate wheel constant calculation).
- Select one constant, e.g.

Wheel 1

(Fig. 55) and press

Calc.

to gain access to the automatic setting function.

- Set the value of the

Reference distance

to be covered.

- Press

F

to start the counting.

- Cover the requested distance: the number of pulses will increase during the path. Stop the tractor at the end of the distance.
- Press

G

to finish the counting. The computer will indicate the calculated constant.

Wheel constant has been saved.