9 tank, 10 filling flowmeter, 9 tank 12.10 filling flowmeter – ARAG GCS 3200 User Manual

Page 22: Tab. 8, Advanced setup

Advertising
background image

22

12.9

Tank

Fig. 40

Fig. 41

Set tank capacity and range value:

Capacity

: indicate the tank capacity.

Minimum level alarm.

: indicate the range value.

The tank alarm activates when during the treatment the tank level falls below the set value.

12.10

Filling flowmeter

Fig. 42

Fig. 43

The filling flowmeter installed in the system allows displaying the tank filling data in real time.

Type

: indicate the filling flowmeter installed and the relevant data.

Tab. 8 contains the values that will be automatically set by selecting the flowmeter code. Nevertheless the constant can be modified.

Constant

: indicate the constant of the installed filling flowmeter.

orion flowMeters

TYPE

UNIT OF MEASUREMENT - METRIC

UNIT OF MEASUREMENT - US

The default values can be modified.

Constant

(pls/l)

Min. rate

(l/min)

Max. rate

(l/min)

Constant

(pls/gal)

Min. rate

GPM

Max. rate

GPM

462xxA4xxxx

300

10,0

200,0

1135

2,60

53,00

4622xA5xxxx

150

20,0

400,0

568

5,00

106,00

4622xA6xxxx

100

30,0

600,0

370

8,00

158,00

Other...

625

10,0

100,0

2366

2,60

53,00

Tab. 8

ADVANCED SETUP