Power components

Select AC or DC power supplies according to the power supply mode of your switch.

Make sure the maximum output power of the power supplies exceeds the system power
consumption. H3C recommends reserving a certain power de-rating value. For the maximum

output power of a single power supply, see

Table 38

.

H3C recommends you to configure N+1 or N+M power supply redundancy.

To use AC power supply, select the specific 16 A AC power cords. For the 16A AC power cords
used in different countries or regions, see

Table 39

.

An NEPS3500-A AC power frame can function properly only after you install one or two
NEPS1800-A AC sub power supplies to it.

Table 38 Electrical parameters of power supplies

Model Description

Rated input

voltage range

Max. input

voltage range

Max.

input

current

Max. output power

NEPS3500-
A

3500 W AC
power frame

N/A N/A

N/A

3500 W (when
installed with two AC

sub power supplies)

NEPS1800-
A

1800 W AC
sub power

supply

100 VAC to 120
VAC; 50 Hz or 60

Hz
200 VAC to 240

VAC; 50 Hz or 60
Hz

90 VAC to 264
VAC; 50 Hz or

60 Hz

20 A

1200 W (100 VAC to
120 VAC)
1800 W (200 VAC to

240 VAC)

NEPS2000-

D

2000 W DC

power supply

–48 VDC to –60

VDC

–40 VDC to –72

VDC

60 A

2000 W

NEPS3500-
D

3500 W DC
power supply

–48 VDC to –60
VDC

–40 VDC to –72
VDC

80 A

3500 W

Table 39 16A AC power cords used in different countries or regions

No. Specifications

1

Connec
tor type

Code (Length)

Countries or regions
where the type of

power cords conforms
to local safety

regulations and can be

used legally

Other countries or
regions using this type of

power cords

Countries or
regions seldom
using this type of

power cords

I type

04043396 (3
m, i.e., 9.8 ft) Mainland China

Connector outline

Power cord outline

Connector outline