Displaying the power supply system of your switch – H3C Technologies H3C S9500E Series Switches User Manual

Page 68

Advertising
background image

58

Displaying the power supply system of your switch

Use the display power-supply command to display the power supply system of your switch.

In standalone mode:

<Sysname> display power-supply verbose

PSU 1 state: Normal

PSU 2 state: Fault

Line-card power status:

Slot Board-Type Watts Status

---- --------------- ----- ------

2 None -- Absent

3 None -- Absent

4 None -- Absent

5 None -- Absent

6 None -- Absent

In IRF mode:

<Sysname> display power-supply verbose

Power info on chassis 1:

PSU 1 state: Normal

PSU 2 state: Absent

Line-card power status:

Slot Board-Type Watts Status

---- --------------- ----- ------

2 LSR1GT24LEC1 85 On

3 LSR1GP48LEC1 115 On

4 None -- Absent

5 Unknown 200 Wait

6 LSR1GT24LEC1 85 On

Table 16 Command output

Field Description

PSU x state:

State of power supply x.

Line-card power status:

Power status of each line card.

Status

Power supply status of the card:

on—The card is normally supplied with power.

absent—The card is not in the slot.

wait—The card is to be supplied with power.

off—The card is unsolicitedly powered off due to user

operation or over-temperature protection.

Power info on chassis 1

Information about the power supply on the member switch 1.

Advertising