66

module to identify the fault source or examine the key parameters monitored by the digital diagnosis

function, including the temperature, voltage, laser bias current, TX power, and RX power.
To diagnose transceiver modules:

Task Command

Remarks

Display alarms present on the
transceiver module in a specified

interface.

display transceiver alarm interface
[ interface-type interface-number ]

Available for all transceiver
modules

Display the present measured
values of the digital diagnosis
parameters for the transceiver

module in a specified interface.

display transceiver diagnosis
interface [ interface-type

interface-number ]

Available for all transceiver
modules

# Display the alarm information about the transceiver module plugged in GigabitEthernet 3/0/1.

<Sysname> display transceiver alarm interface GigabitEthernet 3/0/1

GigabitEthernet3/0/1 transceiver current alarm information:

TX fault

Table 22 Command output

Field Remarks

SFP

RX loss of signal

Received signals are lost.

TX fault

Transmission error.

RX power high

The received optical power is high.

RX power low

The received optical power is low.

TX power high

The transmitted optical power is high.

TX power low

The transmitted optical power is low.

TX bias high

The transmitted bias current is high.

TX bias low

The transmitted bias current is low.

Temp high

The temperature is high.

Temp low

The temperature is low.

Voltage high

The voltage is high.

Voltage low

The voltage is low.

Transceiver info I/O error

Transceiver information read and write error

Transceiver info checksum error

Transceiver information checksum error

Transceiver type and port configuration mismatch

The type of the transceiver module does not match the
port configuration.

Transceiver type not supported by port hardware

The port does not support this type of transceiver
modules.

XFP

RX loss of signal

Received signals are lost.

RX not ready

The receiving status is not ready

Advertising