Assign downlink bandwidth for an onu – H3C Technologies H3C S7500E Series Switches User Manual

Page 98

Advertising
background image

13-9

High-priority packet buffering takes effect for downlink traffic only when downlink bandwidth allocation

policy is enabled (as shown in

Configure traffic policing for downlink/uplink traffic of a UNI

).

Assign downlink bandwidth for an ONU

When an S7500E works as an OLT in an EPON system, you can limit the rate at which the OLT port

sends traffic to each ONU, that is, assign downlink bandwidth to each ONU. This function includes two

configurations:

z

Enabling the downlink bandwidth allocation policy.

z

Configuring the ONU downlink bandwidth range, including the maximum bandwidth and the

maximum burst buffer.

Follow these steps to configure the ONU bandwidth allocation and related parameters:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter ONU port view

interface interface-type

interface-number

Enable the ONU downlink

bandwidth allocation policy

and prioritize high-priority

packets

bandwidth downstream policy

enable

Required

By default, the downlink bandwidth

allocation policy is disabled and

high-priority packets are not

prioritized.

Configure the ONU downlink

bandwidth limit

bandwidth downstream

{ max-bandwidth value |

max-burstsize value } *

Optional

By default, the maximum

bandwidth is 999994 kbps, and the

maximum burst buffer is 8388480

bytes.

z

The configuration of high-priority packet buffering (as shown in

Sending buffer size of the OLT port

)

and that of the downlink bandwidth limit take effect only when the downlink bandwidth allocation

policy is enabled.

z

The configured downlink bandwidth limitation takes effect only on known unicasts, but not on

unknown unicasts, multicasts, or broadcasts.

z

The sum of the minimum uplink bandwidths configured for all the existing ONU ports under an

OLT port cannot exceed 921600 Kbps, namely, 900 Mbps.