Ac power socket (recommended), Connecting the ac power cord, Connecting the dc power cord – H3C Technologies H3C MSR 50 User Manual

Page 32: Dc power supply

Advertising
background image

24

Figure 19 Power socket on AC-powered units

(1)

(2)

(1) Power switch

(2) AC input

AC power socket (recommended)

You are recommended to use a three-terminal single-phase power socket with ground contact, which

must be grounded reliably. Normally, the ground contact of the power supply system in a building was

buried during construction and cabling. Still, before connecting the AC-input power cord, you must make

sure that the power supply of the building is well grounded.

Connecting the AC power cord

Step1

Make sure that the PGND is securely connected to the earth ground.

Step2

Insert one end of the power cord accompanying the router into the power socket on the chassis rear

panel, and fix the cable onto the cable-retention clip with a cable strap. Connect the other end of the

cable to an AC power source at your installation site.

Step3

Place the power switch of the router to the ON position.

Step4

Check that the PWR LED on the front panel of the router is on for correct connection.

Connecting the DC Power Cord

DC power supply

Rated voltage range: –60 VDC to –48 VDC
The following figure illustrates the power socket and switch for a DC-powered router:

Figure 20 Power socket on DC-powered router

(1)

(2)

(1) Power switch

(2) DC input

Advertising