57

CopperHead 3430AP

User Manual

Note: See the Available Power Output and Derating Chart for the HDX-Plus/CH3430AP Power Plus
system on page 25.
The maximum cable length varies due to optical loss that can depend on cable
quality, dirt/dust/contamination on connectors and the number of cable connectors. When using
hybrid cable for camera power, the size of the hybrid cable, as well as the power draw of the camera,
lens, viewfinder and othjer accessories are also factors.

Mechanical/Environmental

Power consumption - camera unit .......................................................................8 W @ 10-18 VDC

Operating temperature range .......................................................................................-25°C to 55°C

Cooling fan speed- 2 fans per frame........ Low (max 20 bB w/camera), High, Auto and Off

Note: When the fan status is Low or Off, an LED indicates if the temperature is too high

Operating humidity range ............................................................ 0 to 95% RH, non-condensing