Grass Valley K2 Storage System Instruction Manual v.3.2 Nov.18 2008 User Manual
Page 160
160
K2 Storage System Instruction Manual
July 15, 2008
Chapter 4 Installing the Level 20 Storage System
b. Leave Full Bind unchecked. Refer to
“About full/background bind” on
.
c. In the
Bind Type
drop down box, select
RAID 5
or
RAID 6
, as specified by your
system design.
d. In the Available Disks box, select six contiguous disks at the top of the list. (TIP:
Use ‘shift-click’ or ‘control-click’ to select disks.).
e. Click the add (arrow) button to add disks to the Selected Disks list.
NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click
Identify Disks.
This causes the disk drive light to flash.
f. Click
OK
to close the Bind dialog box and begin the binding process. The
Progress Report dialog box opens, showing the status of the binding process.